Extracts stream information and time windows from an event.
scevtstreams reads all picks of an event and determines the time window between the first pick and the last pick. In addition a time margin is added to this time window. It writes the streams that are picked including the determined time window for the event to stdout. This tool gives appropriate input information for scart to archive event based data.
Create a playback of an event with a time window of 5 minutes data and sort the records by end time:
scevtstreams -E gfz2012abcd -d mysql://sysop:sysop@localhost/seiscomp3 -L 0 -m 300 |
scart -dsvE --list - ~/seiscomp3/acquisition/archive > gfz2012abcd-sorted.mseed
scevtstreams inherits global options.
show help message.
show version information
Use alternative configuration file. When this option is used the loading of all stages is disabled. Only the given configuration file is parsed and used. To use another name for the configuration create a symbolic link of the application or copy it, eg scautopick -> scautopick2.
Load given plugins.
Run as daemon. This means the application will fork itself and doesn't need to be started with &.
Enable/disable self-shutdown because a master module shutdown. This only works when messaging is enabled and the master module sends a shutdown message (enabled with --start-stop-msg for the master module).
Sets the name of the master-module used for auto-shutdown. This is the application name of the module actually started. If symlinks are used then it is the name of the symlinked application.
Sets the name of the master-username of the messaging used for auto-shutdown. If "shutdown-master-module" is given as well this parameter is ignored.
Verbosity level [0..4]. 0:quiet, 1:error, 2:warning, 3:info, 4:debug
Increase verbosity level (may be repeated, eg. -vv)
Quiet mode: no logging output
Limits the logging to a certain component. This option can be given more than once.
Use syslog logging back end. The output usually goes to /var/lib/messages.
Path to lock file.
Send log output to stdout.
Debug mode: --verbosity=4 --console
Use alternative log file.
List all supported database drivers.
The database connection string, format: service://user:pwd@host/database. "service" is the name of the database driver which can be queried with "--db-driver-list".
The configmodule to use.
Load the inventory database from a given XML file.
Do not use the database at all
Specifies the event id.
Time margin in seconds added to the final stream time window, default 300.
Comma separated list of streams per station to add, e.g. BH,SH,HH.
Specifies whether to use all components (0) or just the picked one (1), default 1.
Specifies whether to use all location codes (0) or just the picked one (1), default 1.